References
- T.F. Tang, Optimization of compound scale corrosion inhibitor
formula for circulating cooling water, Environ. Sci. Technol., 27
(2004) 126–128.
- C.F. Wei, L Hong, B.F. Liang, Status and development of
corrosion and scale inhibitors for circulating cooling water, Sci.
Technol. LCIC, 5 (2000) 126–128.
- D.M. Wei, Treatment of circulating cooling water in re-frigeration
system, Technol. Dev. Chem. Ind., 1 (2011) 42–57.
- R. Touir, N. Dkhireche, M. Ebn Touhami, M. Sfaira, O. Senhaji,
J.J. Robin, B. Boutevin, M. Cherkaoui, Study of phosphonate
addition and hydrodynamic conditions on ordinary steel
corrosion inhibition in simulated cooling water, Mater. Chem.
Phys., 122 (2010) 1–9.
- Z. Quan, C. Wang, B. Li, Y. Chen, C. Ma, Experimental study
of circulating cooling water scale inhibition by low voltage
electrostatic, Water Purif. Technol., 6 (2007) 1–9.
- F. Tang, A.P. Zheng, Z.Z. Song, Research progress and
application of scale inhibitors for industrial circulating cooling
water, Sci. Technol. Chem. Ind., 3 (2010) 1–9.
- Y. Wang, Mechanism and control countermeasures of scale and
corrosion in circulating water, Petrochem. Technol., 7 (2017) 43.
- E. Ilhan-Sungur, A. Otuk, Microbial corrosion of galvanized
steel in a simulated recirculating cooling tower system, Corros.
Sci., 52 (2010) 161–171.
- H. Yue, J.C. Gao, Application and development of corrosion and
scale inhibitor in industrial circulating cooling water treatment,
Xinjiang Oil Gas, 5 (2009) 88–91.
- C.A. Wallace, New developments in disinfection and
sterilization, Am. J. Infect. Control, 44 (2015) 23–27.
- Z. Liu, X. Gao, J. Zhao, The sterilization effect of solenoid
magnetic field direction on heterotrophic bacteria in circulating
cooling water, Procedia Eng., 174 (2017) 1296–1302.
- L.L. Machuca, K. Lepkova, A. Petroski, Corrosion of carbon steel
in the presence of oilfield deposit and thiosulphate-reducing
bacteria in CO2 environment, Corros. Sci., 129 (2017) 16–25.
- M.A. Deyab, Efficiency of cationic surfactant as microbial
corrosion inhibitor for carbon steel in oilfield saline water,
J. Mol. Liq., 255 (2018) 550–555.
- B. Wu, D. Zhong, J.L. Zhang, Application of chlorine dioxide in
circulating cooling water system in power plant, Hebei Electric
Power, 26 (2007) 39–40, 48.
- G. Wen, X.Q. Xu, T.L. Huang, Inactivation of three genera of
dominant fungal spores in groundwater using chlorine dioxide:
effectiveness, influencing factors, and mechanisms, Water Res.,
125 (2017) 132–140.
- Chemical branch of China engineering construction
standardization association, Code for design of industrial
recirculating cooling water treatment (GB50050-17), China
planning press.
- H. Song, D.L. Xi, Study on corrosion about chlorine dioxide on
metal, Journal of China Text. Univ., 24 (1998) 83–86.
- C.W. Cui, L. Zhang, Y.J. Jiao, Study on the Disinfection Effects
of Circulating Cooling Water by Chlorine Dioxide, The First
Academic Seminar of Chlorine Dioxide Professional Committee
of National Chemical Standards Committee, 2005, pp. 118–124.
- Z.F. Cui, Y.C. Han, L.J. Zhuang, Corrosion behaviour and
mechanism of metal in Cl– environment, Corros. Protect.
Petrochem. Ind., 28 (2011) 1–5.
- Z. Panossian, N.L. Almeida, R.M.F. Sousa, Corrosion of carbon
steel pipes and tanks by concentrated sulfuric acid: a review,
Corros. Sci., 58 (2012) 1–11.
- W. Shumei, D. Hongqi, L. Lihua, Electrochemical Analysis of
304 Stainless Steel Corrosion in Chlorine Dioxide, International
Symposium on Emerging Technologies of Pulping and
Papermaking, 2010 pp. 1256–1259.
- Z.J. Kang, K.T. Wang, H.D. Zhao, Corrosion of common metal
in chlorine dioxide disinfectant, Corros. Protect., 31 (2010)
984–985.