References

  1. T.F. Tang, Optimization of compound scale corrosion inhibitor formula for circulating cooling water, Environ. Sci. Technol., 27 (2004) 126–128.
  2. C.F. Wei, L Hong, B.F. Liang, Status and development of corrosion and scale inhibitors for circulating cooling water, Sci. Technol. LCIC, 5 (2000) 126–128.
  3. D.M. Wei, Treatment of circulating cooling water in re-frigeration system, Technol. Dev. Chem. Ind., 1 (2011) 42–57.
  4. R. Touir, N. Dkhireche, M. Ebn Touhami, M. Sfaira, O. Senhaji, J.J. Robin, B. Boutevin, M. Cherkaoui, Study of phosphonate addition and hydrodynamic conditions on ordinary steel corrosion inhibition in simulated cooling water, Mater. Chem. Phys., 122 (2010) 1–9.
  5. Z. Quan, C. Wang, B. Li, Y. Chen, C. Ma, Experimental study of circulating cooling water scale inhibition by low voltage electrostatic, Water Purif. Technol., 6 (2007) 1–9.
  6. F. Tang, A.P. Zheng, Z.Z. Song, Research progress and application of scale inhibitors for industrial circulating cooling water, Sci. Technol. Chem. Ind., 3 (2010) 1–9.
  7. Y. Wang, Mechanism and control countermeasures of scale and corrosion in circulating water, Petrochem. Technol., 7 (2017) 43.
  8. E. Ilhan-Sungur, A. Otuk, Microbial corrosion of galvanized steel in a simulated recirculating cooling tower system, Corros. Sci., 52 (2010) 161–171.
  9. H. Yue, J.C. Gao, Application and development of corrosion and scale inhibitor in industrial circulating cooling water treatment, Xinjiang Oil Gas, 5 (2009) 88–91.
  10. C.A. Wallace, New developments in disinfection and sterilization, Am. J. Infect. Control, 44 (2015) 23–27.
  11. Z. Liu, X. Gao, J. Zhao, The sterilization effect of solenoid magnetic field direction on heterotrophic bacteria in circulating cooling water, Procedia Eng., 174 (2017) 1296–1302.
  12. L.L. Machuca, K. Lepkova, A. Petroski, Corrosion of carbon steel in the presence of oilfield deposit and thiosulphate-reducing bacteria in CO2 environment, Corros. Sci., 129 (2017) 16–25.
  13. M.A. Deyab, Efficiency of cationic surfactant as microbial corrosion inhibitor for carbon steel in oilfield saline water, J. Mol. Liq., 255 (2018) 550–555.
  14. B. Wu, D. Zhong, J.L. Zhang, Application of chlorine dioxide in circulating cooling water system in power plant, Hebei Electric Power, 26 (2007) 39–40, 48.
  15. G. Wen, X.Q. Xu, T.L. Huang, Inactivation of three genera of dominant fungal spores in groundwater using chlorine dioxide: effectiveness, influencing factors, and mechanisms, Water Res., 125 (2017) 132–140.
  16. Chemical branch of China engineering construction standardization association, Code for design of industrial recirculating cooling water treatment (GB50050-17), China planning press.
  17. H. Song, D.L. Xi, Study on corrosion about chlorine dioxide on metal, Journal of China Text. Univ., 24 (1998) 83–86.
  18. C.W. Cui, L. Zhang, Y.J. Jiao, Study on the Disinfection Effects of Circulating Cooling Water by Chlorine Dioxide, The First Academic Seminar of Chlorine Dioxide Professional Committee of National Chemical Standards Committee, 2005, pp. 118–124.
  19. Z.F. Cui, Y.C. Han, L.J. Zhuang, Corrosion behaviour and mechanism of metal in Cl– environment, Corros. Protect. Petrochem. Ind., 28 (2011) 1–5.
  20. Z. Panossian, N.L. Almeida, R.M.F. Sousa, Corrosion of carbon steel pipes and tanks by concentrated sulfuric acid: a review, Corros. Sci., 58 (2012) 1–11.
  21. W. Shumei, D. Hongqi, L. Lihua, Electrochemical Analysis of 304 Stainless Steel Corrosion in Chlorine Dioxide, International Symposium on Emerging Technologies of Pulping and Papermaking, 2010 pp. 1256–1259.
  22. Z.J. Kang, K.T. Wang, H.D. Zhao, Corrosion of common metal in chlorine dioxide disinfectant, Corros. Protect., 31 (2010) 984–985.