  1. S.N. Rai, G.N. Tiwari, Single basin solar still coupled with flat plate collector, Energy Convers. Manage., 23 (1983) 145–149.
  2. S. Suneja, G.N. Tiwari, Effect of water depth on the performance of an inverted absorber double basin solar still, Energy Convers. Manage., 40 (1999) 1885–1897.
  3. O.O. Badran, H.A. Al-Tahaineh, The effect of coupling flat plate collector on the solar still productivity, Desalination, 183 (2004) 137–142.
  4. A.J.N. Khalifa, A.M. Hamood, On the verification of the effect of water depth on the performance of basin type solar stills, Sol. Energy, 83 (2009) 1312–1321.
  5. H. Taghvaei, H. Taghvaei, J. Khosrow, M.R.K. Estahbanati, M. Feilizadeh, M. Feilizadeh, A.S. Ardekani, A thorough investigation of the effects of water depth on the performance of active solar stills, Desalination, 347 (2014) 77–85.
  6. M. Feilizadeh, M.R.K. Estahbanati, A. Ahsan, K. Jafarpur, A. Mersaghian, Effects of water and basin depths in single basin solar stills: an experimental and theoretical study, Energy Convers. Manage., 122 (2016) 174–181.
  7. D.B. Singh, G.N. Tiwari, Performance analysis of basin type solar stills integrated with N identical photovoltaic thermal (PVT) compound parabolic concentrator (CPC) collectors: a comparative study, Sol. Energy, 142 (2017) 144–158.
  8. A.E. Kabeel, R. Sathyamurthy, S.W. Sharshir, A. Muthumanokar, H. Panchal, N. Prakash, C. Prasad, S. Nandakumar, M.S. El Kady, Effect of water depth on a novel absorber plate of pyramid solar still coated with TiO2 nano black paint, J. Cleaner Prod., 213 (2018) 185–191.
  9. D.B. Singh, N. Kumar, Harender, S. Kumar, S.K. Sharma, A. Mallick, Effect of depth of water on various efficiencies and productivity of N identical partially covered PVT collectors incorporated single slope solar distiller unit, Desal. Water Treat., 138 (2019) 99–112.
  10. A.E. Kabeel, S.W. Sharshir, G.B. Abdelaziz, M.A. Halim, A. Swidan, Improving performance of tubular solar still by controlling the water depth and cover cooling, J. Cleaner Prod., 233 (2019) 848–856.
  11. A.M. Manokar, Y. Taamneh, A.E. Kabeel, W.D. Prince, P. Vijayabalan, D. Balaji, R. Sathyamurthy, S.S. Padmanaba, D. Mageshbabu, Effect of water depth and insulation on the productivity of an acrylic pyramid solar still – an experimental study, Groundwater Sustainable Dev., 10 (2020) 100319, doi: 10.1016/j.gsd.2019.100319.
  12. K.V. Modi, K.H. Nayi, S.S. Sharma, Influence of water mass on the performance of spherical basin solar still integrated with parabolic reflector, Groundwater Sustainable Dev., 10 (2020) 100299, doi: 10.1016/j.gsd.2019.100299.
  13. D.B. Singh, Sensitivity analysis of N identical evacuated tubular collectors integrated double slope solar distiller unit by incorporating the effect of exergy, Int. J. Exergy, 34 (2021) 424–447.
  14. M. Gül, E. Akyüz, Energy and exergy analysis of solar photovoltaic thermal system: experimental and numerical verification, Int. J. Exergy, 34 (2021) 16–28.
  15. S.K. Sharma, A. Mallick, D.B. Singh, G.N. Tiwari, Experimental study of solar energy–based water purifier of single-slope type by incorporating a number of similar evacuated tubular collectors, Environ. Sci. Pollut. Res., 29 (2022) 6837–6856.
  16. R. Kumar, D.B. Singh, A. Dewangan, V.K. Singh, N. Kumar, Performance of evacuated tube solar collector integrated solar desalination unit—a review, Desal. Water Treat., 230 (2021) 92–115.
  17. A. Raturi, R. Dobriyal, R.K. Sharma, A. Dwivedi, S.P. Singh, D.B. Singh, Sensitivity investigation for solar still of double slope type included with N similar CPC integrated ETC by incorporating yield and efficiency, Desal. Water Treat., 244 (2021) 12–26.
  18. A. Raturi, D.B. Singh, P. Patil, A.K. Sharma, Sensitivity analysis of solar still of single slope type included with N similar evacuated tubular collectors having series connection, Desal. Water Treat., 234 (2021) 309–323.
  19. D.B. Singh, D. Kumar, R.K. Yadav, S.K. Sharma, N. Kumar, V.K. Dwivedi, An investigation of effect of mass flow rate variation on productivity, exergoeconomic and enviroeconomic parameters on N similar PVTCPCs included with double slope solar still, Desal. Water Treat., 243 (2021) 1–17.
  20. D.B. Singh, R.K. Yadav, Y. Chaturvedi, M. Kumar, G.K. Sharma, N. Kumar, Study on effect of dissimilarity of mass flow rate on energy metrics of solar energy based double slope water purifier by incorporating N alike PVT compound parabolic concentrator collectors, Desal. Water Treat., 231 (2021) 27–43.
  21. D.B. Singh, R.K. Yadav, Y. Chaturvedi, G.K. Sharma, S.K. Sharma, N. Kumar, Effect of Water Depth on Efficiencies and Productivity of N Alike Evacuated Tubular Solar Collectors Coupled to Solar Still of Single Slope Type by Incorporating Exergy, TUBA World Conference on Energy Science and Technology (TUBA WCEST-2021), Turkish Academy of Science, Ankara, Turkey, August 8–12, 2021.
  22. D.P. Kumar, G. Mittal, R.K. Sharma, D.B. Singh, S. Tiwari, Review on performance assessment of solar stills using computational fluid dynamics (CFD), Environ. Sci. Pollut. Res., 29 (2022) 38673–38714.
  23. R.K. Mishra, V. Garg, G.N. Tiwari, Thermal modeling and development of characteristic equations of evacuated tubular collector (ETC), Sol. Energy, 116 (2015) 165–176.
  24. D.B. Singh, V.K. Dwivedi, G.N. Tiwari, N. Kumar, Analytical characteristic equation of N identical evacuated tubular collectors integrated single slope solar still, Desal. Water Treat., 88 (2017) 41–51.
  25. Y.A. Çengel, M.A. Boles, Thermodynamics: An Engineering Approach, McGraw Hill Education (India) Private Limited, New Delhi, 2016.
  26. R. Petela, Exergy of undiluted thermal radiation, Sol. Energy, 86 (2003) 241–247.
  27. International Labor Office, Introduction to Work Study, International Labor Organization, Geneva, 1979.
  28. J.A. Duffie, W.A. Beckman, Solar Engineering of Thermal Processes, John Wiley & Sons, Inc., Hoboken, New Jersey, 2013.
  29. B.Y.H. Liu. R.C. Jordan, Daily insolation on surfaces tilted towards equator, ASHRAE J., 3 (1962) 53.
  30. D.B. Singh, G.N. Tiwari, Energy, exergy and cost analyses of N identical evacuated tubular collectors integrated basin type solar stills: a comparative study, Sol. Energy, 55 (2017) 829–846.